|
|
|
|
 |
 |
|
Simple Method to run a series of subjects:
Start system:
1. Shortcut: BrainMaster Setup (bsetup.exe) 2. Log in if necessary (see below)
3. Check entry in “Current Trainee/Study Folder”. If OK, proceed to (7) 4. If you want a different folder, click on “Folder Selections”
If Existing Subject: 5. Select Subject from list 6. Click on “OK”
If New Subject:
7. Click on “Create New Folder” 8. Enter first & last name into “Name” area. ID will be filled in automatically
9. Click on “OK” 10. Inspect new name and ID. Make changes if desired 11. Click on “OK”
12. Select desired starting settings from list 13. Click on “OK” 14. Inspect settings, make changes if desired
15. Click on “Use These Settings”
Run Training Screen 16. Click on “Run the Next Session”
17. In “Preparing to Begin Session” dialog, click on “OK” 18. In “Begin Session” dialog, click on “OK” 19. Training Screen appears; Click on “GO”
20. In “Current Date” dialog, click on “OK” 21. View “Ready to Start” dialog; place electrodes; turn on module; click on “OK” 22. System will start working
23. Follow instructions as training begins 24. Use “Window” control to create new display windows if desired
25. To pause, press <Space> bar. Press <Space> bar again to resume
End Training Screen: 26. After session is complete, press “Close” button
Review Result: From bsetup screen OR Setup & Control Home Screen: 26. Menu: Review Session Results 27. Current study and session should appear on graph
27. To select a session: Button: Select (selection box appears) 28. Select Session by number from selection box. 29. Button: OK
30. Stats (view result on screen) 31. Button: Print (prints detailed summary)
Remove electrodes, turn off module
|
|
 |
 |
|
Logging in to BrainMaster
1. Press “Login to BrainMaster” 2. Enter the following information: 3. Serial Number: (your device serial number)
4. PassKey: (use PassKey from BrainMaster Technologies) 5. Click on “Remember PassKey” to save login information
6. Name: Your name, e.g. “John Smith” or “EEG Training Associates” 7. Email: Your email (this will be used to pre-address emails created using Session
Librarian, from folders that you create and distribute 8. Press “OK” 9. Dialog box will appear showing results of login
Note: If
you use “Remember PassKey”, then you will not have to log in again, on that PC. The system will automatically log you in, whenever the software is run.
|
 |
 |
|
Creating, Setting up, and Sending Folders to Remote Trainees
NOTE: files can be sent via. Floppy Disk, email, CD, or any means desired
1. Start software in usual manner 2. Press “Folder Selections”
3. Press “Create New Folder” 4. Input name, ID as appropriate 6. Select Settings File to start with, press “OK”
6. Adjust settings as desired NOTE: Check Number of Sessions, etc. carefully 7. Press “Use These Settings” 8. Press “Folder Selections”
9. Press “Session Librarian” 10. Follow prompts to make Floppy Disk or Email as desired 11.
If neither Floppy or Email are used, the file will be found in: c:\brainm.20\archive and will be named e.g. “smitjohn.bmz”. 12.
You can email or copy the file from the archive directory and provide it to client in any way desired.
13. When trainee receives file, they need only DOUBLE-CLICK on the “bmz” file. 14.
Trainee should follow the prompts, allowing BrainMaster software to unpack and install the file. 15.
The new folder e.g. “smitjohn” will now appear as a choice, when Folder Selections is used on the trainee’s PC.
|
 |
 |
 |
 |
 |
 |
|
Keyboard Functions for BrainMaster 2.0 BMT (Basic Modules for Training)
|
Key
|
Function
|
|
a
|
Increase alpha (8-12 Hz) threshold by 0.1uV or target by 1%
|
|
A
|
Decrease alpha (8-12 Hz) threshold by 0.1uV or target by 1%
|
|
b
|
Increase beta (15-20 Hz) threshold by 0.1uV or target by 1%
|
|
B
|
Decrease beta (15-20 Hz) threshold by 0.1uV or target by 1%
|
|
c
|
Raise coherence threshold
|
|
C
|
Lower coherence threshold
|
|
d
|
Increase delta (1-3 Hz) threshold by 0.1uV or target by 1%
|
|
D
|
Decrease delta (1-3 Hz) threshold by 0.1uV or target by 1%
|
|
e
|
Toggle “Thermometer” display window(s)
|
|
f
|
Toggle FFT “Frequency” display window(s)
|
|
g
|
Increase “gamma” (38-42 Hz) threshold 0.1 uV or target by 1%
|
|
G
|
Decrease “gamma” (38-42 Hz) threshold 0.1 uV or target by 1%
|
|
h
|
Increase “hibeta” (20-38 Hz) threshold 0.1 uV or target by 1%
|
|
H
|
Decrease “hibeta” (20-38 Hz) threshold 0.1 uV or target by 1%
|
|
i
|
Toggle “1-dimensional trend” line graph display window(s)
|
|
j
|
Toggle “2-dimensional trend” line graph display window(s)
|
|
l
|
Increase “lobeta” (12-15 Hz) threshold 0.1 uV or target by 1%
|
|
L
|
Decrease “lobeta” (12-15 Hz) threshold 0.1 uV or target by 1%
|
|
m
|
Toggle “Brain Mirror” between FFT and Filtered Mode
|
|
p
|
Toggle “Phase Space” display window(s)
|
|
r
|
Reduce artifact rejection threshold value by 10 microvolts
|
|
R
|
Increase artifact rejection threshold value by 10 microvolts
|
|
t
|
Increase theta (3-8 Hz) threshold by 0.1 uV or target by 1%
|
|
T
|
Decrease theta (3-8 Hz) threshold by 0.1 uV or target by 1%
|
|
u
|
Increase user band threshold by 0.1 uV or target by 1%
|
|
U
|
Decrease user band threshold by 0.1 uV or target by 1%
|
|
w
|
Toggle “Waveform” display window(s)
|
|
y
|
Update thresholds (when using autothresholding)
|
|
z
|
Stops and Starts data acquisition
|
|
+
|
Increase display gain by 20%
|
|
-
|
Decrease display gain by 20%
|
|
0
|
Set threshold adjust to “both channels” mode
|
|
1
|
Set threshold adjust to “channel 1 only” mode
|
|
2
|
Set threshold adjust to “channel 2 only” mode
|
|
3-9
|
Post Notes 3, 4, 5, 6, 7, 8, 9
|
|
<Tab>
|
Toggle between THRESHOLD and FREQUENCY adjust mode
(Will see frequency component labels highlighted if FREQ mode)
|
|
.
|
(“period” or “decimal point”) Start Data Acquisition
|
|
|
|
Note: In THRESHOLD adjust mode, typed character “t”, “T”, etc.
will change the threshold up or down. If AUTOTHRESHOLD is ON, then the TARGET PERCENTAGE will be changed by 1% (percent) up or down.
If AUTOTHRESHOLD is OFF, then the THRESHOLD VOLTAGE will be changed by 0.1 uV (microvolt) up or down. In FREQUENCY adjust mode, typed character will change the frequency band settings by 0.5 Hz (Hertz = cycles per second) up or down.
|
|
|
|
Built-in Protocols
The following standard settings files are included, and can be selected from the setup program.
|
|
 |
|
|
|
Name
|
Use
|
Published
Application
|
Recommended leads
|
Displays
|
Training
|
|
Alert
|
increase beta suppress theta
|
Focus, Alertness
(Sterman, Lubar)
|
C3 (blue)
left ear (yellow)
right ear (black)
|
waveform, filtered wave, thermometers, filtered mirror
|
beta “go”, theta “stop”, hibeta “stop”, others “ignore”
|
|
Asym
|
Increase right alpha, suppress left alpha
|
Mood
(Rosenfeld, Baehr)
|
F3 (blue)
Cz (yellow, green)
F4 (red)
A1 (black)
|
Waveform, filtered wave, thermometers, Thermos and TrendView
Windows
|
Right alpha “go”, left alpha “stop”
|
|
Deep
|
Increase alpha increase theta
|
Deep Relaxation
(Penniston)
|
Cz (blue)
right or left ear (yellow)
other ear (black)
|
waveform, thermometers, filtered mirror
|
alpha “go”, theta “go”
Note: use with caution, watch for possible abreaction
|
|
Deep2
|
2-channel protocol similar to “deep”
|
Deep Relaxation
(Penniston)
|
C3 (blue) left ear (yellow)
C4 (red) right ear (green)
Cz (black)
|
waveform, thermometers, filtered mirror
|
alpha “go”, theta “go”
Note: use with caution, watch for possible abreaction
|
|
Focus
|
increase lobeta suppress theta
|
Concentration, Focus
(Lubar, Sterman)
|
C4 (blue)
right ear (yellow)
left ear (black)
|
waveform, filtered wave, thermometers, filtered mirror
|
lobeta “go”, theta “stop”, hibeta “stop”, others “ignore”
|
|
Peak
|
alpha coherence
|
Peak performance
(Fehmi/Hardt/
Kamiya)
|
C3 (blue) left ear (yellow)
C4 (red) right ear (green)
Cz (black)
|
waveform, thermometers
|
alpha coherence “up”
|
|
Peak2
|
2-chahnel peak performance
|
Peak performance
(Combined Lubar/Sterman)
|
C3 (blue) left ear (yellow)
C4 (red) right ear (green)
Cz (black)
|
Waveform, thermometers
|
beta “go” channel 1, lobeta “go” channel 2, theta “stop” both channels,
hibeta “stop” both channels, others “ignore”
|
|
Relax
|
increase alpha
|
Relaxation
(Classic alpha protocol)
|
Cz (blue)
either ear (yellow)
other ear (black)
|
waveform, filtered wave, thermometers, filtered mirror
|
alpha “go”, hibeta “stop”, others “ignore”
|
|
Sharp
|
“squash”
|
Mental fitness
(Maust, others)
|
Cz or Fz (blue)
either ear (yellow)
other ear (black)
|
waveform, thermometers, fft mirror
|
theta “stop”, alpha “stop”, lobeta “stop”, beta “stop
|
|
 |
 |
|
Typical 1-channel Connection
|
 |
|
|
|
Active
|
(on Head)
|
Blue
|
|
Indifferent
|
(On Ear)
|
Yellow
|
|
Groung
|
(Other Ear)
|
Black
|
|
 |
 |
|
Typical 2-channel Connection
|
 |
|
|
|
Left Active
|
(on Head)
|
Blue
|
|
Left Reference
|
(Left Ear or Mastoid)
|
Yellow
|
|
Ground
|
(Forehead,Ear or Mastoid)
|
Black
|
|
Right Active
|
(Right Ear or Mastoid)
|
Green
|
|
Right Reference
|
(on Head)
|
Red
|
|
 |
 |
|
This is the 2.0 Training Screen with the “Focus” Protocol
|
 |
 |
 |
 |
 |
 |
|
 |
|
|
THRESHOLD MODE (AUTOTHRESHOLD OFF):
“t”, T”, “a”, “A”, etc. change the THRESHOLDS (microvolts) Changes are 0.1 microvolt up or down
THRESHOLD MODE (AUTOTHRESHOLD ON): “t”, T”, “a”, “A”, etc. change the TARGETS (percentage)
Changes are 1 percent up or down
Use <Tab> to switch between two modes: If Component labels are highlighted: “t”, T”, “a”, “A”, etc. change the FREQUENCY BANDS (cycles/second)
Changes are 0.5 cycles/second up or down (whole band moves)
CHANNEL SELECT MODE : “1” = “channel 1 only”, “2” = “channel 2 only”, “0” = “both channels
|
|
|
|
BrainMaster Technologies, Inc. 24490 Broadway Avenue Oakwood Village, Ohio 44146 Corporate Offices (440) 232-6000 Fax (440) 232-7171 info@brainm.com
|
|
|
|
|