barBMRnew0602
bar
onlinestore02

FIND QUICKLY

bullet 

BrainMaster Software
Software Descriptions
3.0 Download Update
2.5 Downloads/Updates
2.0 Downloads/Updates
2.5
Screen Shots

bullet 

BrainMaster Systems

bullet02 

BrainMaster Product Brochures
Download PDF Files Here

bullet0202 

NEW! Home Users Section - Find out how to start on the road to Neurofeedback Training HERE

bullet0202

All About Remote Training

bullet 

Mythbuster’s Uses BrainMaster to study “Mind Control” myths....
.see the video!

bullet02 

Why BrainMaster ?-The Top 15 Reasons..... about it here

bullet02

NEW Z Score DLL Training - Applied NeuroScience and BrainMaster join together to present new EEG training tool!

bullet02 

Workshops, Conferences and Educational Opportunities

bullet02 

IMPORTANT
Static Information Here

bullet02 

Advice for Parents of ADD/ADHD Children
as seen on the Dr. Phil’s TV Show with Dr. Lawlis, author of The ADD Answer
r

bar02
subheader_r

 

Quick Reference Guide
subheader_r

Simple Method to run a series of subjects:

Start system:
1.       Shortcut: BrainMaster Setup (bsetup.exe)
2.       Log in if necessary (see below)
3.       Check entry in “Current Trainee/Study Folder”. If OK, proceed to (7)
4.       If you want a different folder, click on “Folder Selections”

If Existing Subject:
5.       Select Subject from list
6.       Click on “OK”

If New Subject:
7.       Click on “Create New Folder”
8.       Enter first & last name into “Name” area.  ID will be filled in automatically
9.       Click on “OK”
10.      Inspect new name and ID.  Make changes if desired
11.      Click on “OK”
12.      Select desired starting settings from list
13.      Click on “OK”
14.      Inspect settings, make changes if desired
15.      Click on “Use These Settings”

Run Training Screen
16.    Click on “Run the Next Session”
17.    In “Preparing to Begin Session” dialog, click on “OK”
18.    In “Begin Session” dialog, click on “OK”
19.    Training Screen appears; Click on “GO”
20.    In “Current Date” dialog, click on “OK”
21.    View “Ready to Start” dialog; place electrodes; turn on module; click on “OK”
22.    System will start working
23.    Follow instructions as training begins
24.    Use “Window” control to create new display windows if desired
25.    To pause, press <Space> bar. Press <Space> bar again to resume

End Training Screen:
26.    After session is complete, press “Close” button

Review Result:
From bsetup screen OR Setup & Control Home Screen:
26.    Menu: Review Session Results
27.    Current study and session should appear on graph
27.    To select a session: Button: Select (selection box appears)
28.    Select Session by number from selection box.
29.    Button: OK
30.    Stats (view result on screen)
31.    Button: Print (prints detailed summary)

Remove electrodes, turn off module

Logging in to BrainMaster
 

1.     Press “Login to BrainMaster”
2.     Enter the following information:
3.     Serial Number:  (your device serial number)
4.     PassKey: (use PassKey from BrainMaster Technologies)
5.     Click on “Remember PassKey” to save login information
6.     Name: Your name, e.g. “John Smith” or “EEG Training Associates”
7.     Email:  Your email (this will be used to pre-address emails created using Session               Librarian, from folders that you create and distribute
8.     Press “OK”
9.     Dialog box will appear showing results of login
 

Note: If you use “Remember PassKey”, then you will not have to log in again, on that PC. The system will automatically log you in, whenever the software is run.
 

Creating, Setting up, and Sending Folders to Remote Trainees
 
NOTE: files can be sent via. Floppy Disk, email, CD, or any means desired

1.     Start software in usual manner
2.     Press “Folder Selections”
3.     Press “Create New Folder”
4.     Input name, ID as appropriate
6.     Select Settings File to start with, press “OK”
6.     Adjust settings as desired  NOTE: Check Number of Sessions, etc. carefully
7.     Press “Use These Settings”
8.     Press “Folder Selections”
9.     Press “Session Librarian”
10.  Follow prompts to make Floppy Disk or Email as desired
11.  If neither Floppy or Email are used, the file will be found in: c:\brainm.20\archive and         will be named e.g. “smitjohn.bmz”.
12.  You can email or copy the file from the archive directory and provide it to client in any        way desired.
13.  When trainee receives file, they need only DOUBLE-CLICK on the “bmz” file.
14.  Trainee should follow the prompts, allowing BrainMaster software to unpack and               install the file.
15.  The new folder e.g. “smitjohn” will now appear as a choice, when Folder Selections is        used on the trainee’s PC.
 

Keyboard Functions for BrainMaster 2.0 BMT (Basic Modules for Training)

Key

Function

a

Increase alpha (8-12 Hz) threshold by 0.1uV or target by 1%

A

Decrease alpha (8-12 Hz) threshold by 0.1uV or target by 1%

b

Increase beta (15-20 Hz) threshold by 0.1uV or target by 1%

B

Decrease beta (15-20 Hz) threshold by 0.1uV or target by 1%

c

Raise coherence threshold

C

Lower coherence threshold

d

Increase delta (1-3 Hz) threshold by 0.1uV or target by 1%

D

Decrease delta (1-3 Hz) threshold by 0.1uV or target by 1%

e

Toggle “Thermometer” display window(s)

f

Toggle FFT “Frequency” display window(s)

g

Increase “gamma” (38-42 Hz) threshold 0.1 uV or target by 1%

G

Decrease “gamma” (38-42 Hz) threshold 0.1 uV or target by 1%

h

Increase “hibeta” (20-38 Hz) threshold 0.1 uV or target by 1%

H

Decrease “hibeta” (20-38 Hz) threshold 0.1 uV or target by 1%

i

Toggle “1-dimensional trend” line graph display window(s)

j

Toggle “2-dimensional trend” line graph display window(s)

l

Increase “lobeta” (12-15 Hz) threshold 0.1 uV or target by 1%

L

Decrease “lobeta” (12-15 Hz) threshold 0.1 uV or target by 1%

m

Toggle “Brain Mirror” between FFT and Filtered Mode

p

Toggle “Phase Space” display window(s)

r

Reduce artifact rejection threshold value by 10 microvolts

R

Increase artifact rejection threshold value by 10 microvolts

t

Increase theta (3-8 Hz) threshold by 0.1 uV or target by 1%

T

Decrease theta (3-8 Hz) threshold by 0.1 uV or target by 1%

u

Increase user band threshold by 0.1 uV or target by 1%

U

Decrease user band threshold by 0.1 uV or target by 1%

w

Toggle “Waveform” display window(s)

y

Update thresholds (when using autothresholding)

z

Stops and Starts data acquisition

+

Increase display gain by 20%

-

Decrease display gain by 20%

0

Set threshold adjust to “both channels” mode

1

Set threshold adjust to “channel 1 only” mode

2

Set threshold adjust to “channel 2 only” mode

3-9

Post Notes 3, 4, 5, 6, 7, 8, 9

<Tab>

Toggle between THRESHOLD and FREQUENCY adjust mode

(Will see frequency component labels highlighted if FREQ mode)

.

(“period” or “decimal point”) Start Data Acquisition

Note:  In THRESHOLD adjust mode, typed character “t”, “T”, etc. will change the threshold up or down.  If AUTOTHRESHOLD is ON, then the TARGET PERCENTAGE will be changed by 1% (percent) up or down. If AUTOTHRESHOLD is OFF, then the THRESHOLD VOLTAGE will be changed by 0.1 uV (microvolt) up or down.  In FREQUENCY adjust mode, typed character will change the frequency band settings by 0.5 Hz (Hertz = cycles per second) up or down.

Built-in Protocols

The following standard settings files are included, and can be selected from the setup program.

 

Name

Use

Published

Application

Recommended leads

Displays

Training

Alert

increase beta suppress theta

Focus, Alertness

(Sterman, Lubar)

C3 (blue)

left ear (yellow)

right ear (black)

waveform, filtered wave, thermometers, filtered mirror

beta “go”, theta “stop”, hibeta “stop”, others “ignore”

Asym

Increase right alpha, suppress left alpha

Mood

(Rosenfeld, Baehr)

F3 (blue)

Cz (yellow, green)

F4 (red)

A1 (black)

Waveform, filtered wave, thermometers, Thermos and TrendView Windows

Right alpha “go”, left alpha “stop”

Deep

Increase alpha increase theta

Deep Relaxation

(Penniston)

Cz (blue)

right or left ear (yellow)

other ear (black)

waveform, thermometers, filtered mirror

alpha “go”, theta “go”

Note: use with caution, watch for possible abreaction

Deep2

2-channel protocol similar to “deep”

Deep Relaxation

(Penniston)

C3 (blue) left ear (yellow)

C4 (red) right ear (green)

Cz (black)

waveform, thermometers, filtered mirror

alpha “go”, theta “go”

Note: use with caution, watch for possible abreaction

Focus

increase lobeta suppress theta

Concentration, Focus

(Lubar, Sterman)

C4 (blue)

right ear (yellow)

left ear (black)

waveform, filtered wave, thermometers, filtered mirror

lobeta “go”, theta “stop”, hibeta “stop”, others “ignore”

Peak

alpha coherence

Peak performance

(Fehmi/Hardt/

Kamiya)

C3 (blue) left ear (yellow)

C4 (red) right ear (green)

Cz (black)

waveform, thermometers

alpha coherence “up”

Peak2

2-chahnel peak performance

Peak performance

(Combined Lubar/Sterman)

C3 (blue) left ear (yellow)

C4 (red) right ear (green)

Cz (black)

Waveform, thermometers

beta “go” channel 1, lobeta “go” channel 2, theta “stop” both channels, hibeta “stop” both channels, others “ignore”

Relax

increase alpha

Relaxation

(Classic alpha protocol)

Cz (blue)

either ear (yellow)

other ear (black)

waveform, filtered wave, thermometers, filtered mirror

alpha “go”, hibeta “stop”, others “ignore”

Sharp

“squash”

Mental fitness

(Maust, others)

Cz or Fz (blue)

either ear (yellow)

other ear (black)

waveform, thermometers, fft mirror

theta “stop”, alpha “stop”, lobeta “stop”, beta “stop

Typical 1-channel Connection

Active

(on Head)

Blue

Indifferent

(On Ear)

Yellow

Groung

(Other Ear)

Black

Typical 2-channel Connection

Left Active

(on Head)

Blue

Left Reference

(Left Ear or Mastoid)

Yellow

Ground

(Forehead,Ear or Mastoid)

Black

Right Active

(Right Ear or Mastoid)

Green

Right Reference

(on Head)

Red

This is the 2.0 Training Screen with the “Focus” Protocol

THRESHOLD MODE (AUTOTHRESHOLD OFF):
“t”, T”, “a”, “A”, etc. change the THRESHOLDS (microvolts)
Changes are 0.1 microvolt up or down

THRESHOLD MODE (AUTOTHRESHOLD ON):
“t”, T”, “a”, “A”, etc. change the TARGETS (percentage)
Changes are 1 percent up or down

Use <Tab> to switch between two modes:
If Component labels are highlighted:
“t”, T”, “a”, “A”, etc. change the FREQUENCY BANDS (cycles/second)
Changes are 0.5 cycles/second up or down (whole band moves)

CHANNEL SELECT MODE :
“1” = “channel 1 only”, “2” = “channel 2 only”, “0” = “both channels