Showing: 1-19 of 19  
Articles
 
document HEG
Information on HEG The BrainMaster system can add either of the two main types of HEG systems.  These are nIR ("Toomim") and pIR ("Carmen").  In both cases, an additional head-mounted photelectronic sensor is placed on the trainee, and the system responds to the...
01 May, 2008
document MIDIStim information
MIDIStim is an obsolete product (replaced by the StimFlash). It provided EEG-controlled photic stimulation. You can see it in operation in the following YouTube video: The StimFlash will perform the functions shown in this video.  
20 Mar, 2008
document BrainMaster Serial Port Installation, Configuration, and operation Troubleshooting Information
If you are trying to connect through a serial connection this file can be helpful in making sure you have everything set up correctly.  NOTE: This is for older 2E and 2EW models that have a serial port connection.  For Atlantis and 2EB devices, refer to the USB documentation.
20 Mar, 2008
document Can I connect 2 laptops together to get 2 displays?
To get a second display, you need to attach a separate monitor.  A second laptop will not work in this situation. Each laptop has a video output, but no video input.  So there is no place to plug a video controller cable into a laptop PC. To get a second display, you should get a...
22 Jun, 2008
document StimFlash Information
StimFlash is an external hardware capability that provides EEG-driven photic stimulation. Here is the manual for StimFlash EEG - controlled photic stimulation software.  This device uses the PC sound port to control an Audio-Strobe compatible device.  These include the Nova Pro 100,...
27 Feb, 2008
document Can I use tin electrodes with my BrainMaster unit?
The BrainMaster is fine with tin electrodes.   The old BrainMasters have input impedance of 10 MOhms, and the newer ones have 10GOhm impedance, and the Atlantis has 1000GOhm impedance.  They will work with any conventional electrodes, including tin.   Even with tin, you can...
19 Jan, 2008
document FlexCap information
The FlexCap is a unique 10-20 positioning cap with adapters to hold EEG sensors. See the attachment for additional information.  
20 Mar, 2008
document Can I use BioExplorer on my Atlantis?
Yes, the BioExplorer Enhanced Driver for BrainMaster will operate Atlantis devices. The operate in an "emulation" mode to provide 2 channels of EEG, or HEG in the same way as a 2E module.  
15 Apr, 2008
document Error Opening COM Port
Here is a step by step procedure to help you with this error. Make sure you do not have another copy of the software on your computer Try rebooting your computer Disconnect and other devices from your computer and try the BrainMaster again Ensure the input cable is attached...
20 Mar, 2008
document How Should I Clean My Electrodes?
We find that hot water is the best method. Run it as hot as possible, and hold the electrodes underneath.  You can also soak them for a couple of minutes in the hot water in a glass, then follow with a hot rinse. 10-20 paste is completely water soluble, and hot water makes it thin...
19 Jan, 2008
document In Field Battery Test
Does the light come on when you turn the unit on? Yes - Your battery is in good working condition No - Has the unit been plugged in and turned off for at least 12 hours between uses? Yes - Test the charger No - Plug the unit in and charge it for at least 24 hours.  If this does...
20 Mar, 2008
document 4-channel connection with 2 2-channel cables
The attached drawing shows how to connect 4 channels using 2 2-channel cables and 3 jumpers
19 Feb, 2008
document Module Not Responding
Goto In Field Battery Test Does the charger function properly? No - Contact BrainMaster Technologies, 440-232-6000, and obtain an RGA # for a replacement charger. Yes - Try using your unit on another computer. (If you do not have another computer proceed to
20 Mar, 2008
document What are FlexTrodes?
Flextrodes are a unique EEG sensor placement system that uses special fittings to hold gold disks inside a felt-lined compartment.  These are held on the head using velcro strips.  The Flextrode system is patented (US Patent #6,574,513) Additional information can be found at: ...
19 Jan, 2008
document Atlantis Technical Information - Sensory Immersion Stimulation, Triamp
All Atlantis devices have built-in "autonomous" sensory immersion outputs.  These provide visual, auditory, and vibrotactile output. The autonomous mode currently has no protocols or  threshold settings.  It uses a completely new concept, one of sensory  immersion...
15 Apr, 2008
document My EEG signal is not very clean. What do I do?
If the signal is experiencing noise you can try several things to fix this problem: Try moving the BrainMaster farther away from the computer Unplug the unit from its charger If you are using a laptop, unplug the AC adapter Try braiding the electrodes together to try to cancel...
20 Mar, 2008
document Error Messages on Start Up
This is when you are in the training screen and click GO Module is Dead, Cable is Disconnected, or COM Port is Wrong or keyboard/mouse is on that port Dialog Box with: No response on COM Port
03 Jul, 2007
document Intermittent PC COMM Errors can be caused by a weak battery (2E and 2EW)
We are having a problem when training, an error message stalls the session.  The error message is PC COMM ERROR and some other stuff that makes no sense to me.  It happens at least 7 - 12 times during the training session, both front and back.  It didn't happen during our first week...
19 Sep, 2007
document Firmware Upgrade for Atlantis
This article provides information on upgrading the firmware in an Atlantis amplifier You must first have the 3.2.2 software loaded from Then go to and type "firmware" into the search box. Then select the article "Full Atlantis Programming" for details. You are...
02 Jun, 2008